CENTAVR CEN1252AIRM combines oxidation with atmospheric oxygen (AIR technology) and catalytic filtration using Manganox media.
The system operates automatically and does not require salt or regular chemical replenishment.
How does CEN1252AIRM work?
The automatic control periodically restores an air zone inside the upper part of the filter vessel.
Incoming water first comes into contact with air. Atmospheric oxygen promotes the oxidation of dissolved iron before the water passes through a specially designed multi-layer filtration bed containing Manganox catalytic media.
Oxidised iron and manganese compounds are retained in the filtration bed and periodically discharged to drain during automatic backwashing.
AIR technology
CEN1252AIRM does not require a separate air compressor or external aeration tank.
During the automatic regeneration cycle, atmospheric air is drawn into the system to restore the required air zone inside the vessel.
The air intake assembly incorporates John Guest components and a non-return valve.
Manganox catalytic filtration
Manganox is a catalytic filtration medium with a high content of active manganese oxides. Its catalytic surface promotes iron and manganese oxidation and helps retain the resulting insoluble particles.
In CEN1252AIRM, Manganox is combined with specially selected layers of graded quartz filtration media.
Automatic Clack control
The system is equipped with a Clack WS1 CE automatic control valve.
The controller manages normal filtration, backwashing, air-zone restoration and rinsing automatically.
Key advantages
- AIR oxidation combined with Manganox catalytic filtration
- no salt required
- no regular chemical dosing
- automatic Clack WS1 CE control
- John Guest air-intake components
- aeration and filtration within one compact 1252 vessel
- automatic removal of accumulated contaminants
Technical specifications
| Parameter | CEN1252AIRM |
|---|---|
| Vessel | 1252 |
| Control valve | Clack WS1 CE |
| Technology | AIR + Manganox |
| Filter media | Manganox + multi-layer graded quartz |
| Nominal flow rate | ~0.9 m³/h |
| Recommended service flow | 0.6-1.2 m³/h |
| Short-term peak flow | up to ~1.5 m³/h |
| Required backwash flow | at least ~2.2 m³/h |
| Water consumption per backwash | approx. 0.30-0.40 m³* |
| Typical backwash interval | every 3-4 days* |
| Connection | 1″ |
| Recommended operating pressure | from 2.5 bar |
| Power supply | 230 V |
| Salt required | No |
| Regular chemical dosing | No |
* Actual values depend on raw-water quality, pressure and system settings.
Selecting the correct system
Before selecting CEN1252AIRM, we recommend testing at least Fe, Mn, pH, NH₄, permanganate index/organic matter, water hardness and electrical conductivity.
The actual well-pump capacity must also be considered because sufficient flow at operating pressure is essential for effective backwashing.
CEN1252AIRM is not a water softener. Elevated hardness, ammonium, organic matter or other specific contaminants may require additional treatment stages.
Send us your water analysis and CENTAVR specialists will evaluate the water quality and recommend the appropriate treatment solution.