ECOPRO440 Membrane element for an industrial system:
| Nominal active area: | 41 m² |
| Working pressure: | 10,3 bar |
| Penetrability power: | 48 m3 / day |
| Selectivity: | 99,7 % |
| Maximum working water temperature: | 45 °С |
| Maximum working pressure: | 41 bar |
| Maximum differential pressure: | 1,0 bar |
| pH range, working mode: | 2 – 11 |
| pH range, chem. flushing: | 1 – 12 |
| Maximum SDI Index: | SDI<5 |
| Permissible amount of free chlorine: | <0,1 mg/l |
1. Permeate flow rate and selectivity are given for the following conditions: 2000 mg/l NaCl, 25°C, pH 8, over pressure and 15% permeate yield.
2. Permeate flow rate for a specific element may differ from the given values by ±15%.
SERVICE
Membrane element for industrial system ECOPRO440
Before starting the reverse osmosis system it is necessary to prepare the membrane element- calibrate the instruments and perform other system checks. Avoid sudden pressure or flow changes in the membrane elements to prevent damage during start-up, shutdown and flushing.
During the startup it is recommended to gradually switch the reverse osmosis system from the rest to the operation mode:
- the source water pressure should be raised within 30-60 seconds;
- the flow rate should be reached within 15-20 seconds;
- the permeate obtained in the first hour of operation should be discarded.
IMPORTANT INFORMATION
- Keep the membrane elements moist after initial moisturizing;
- To prevent membrane from biological pollution during the long downtimes, it is recommended to immerse the membrane elements in the preservative solutions;
- The maximum differential pressure along the entire body length is 2.1 bar.